MCQOPTIONS
Saved Bookmarks
This section includes 9 Mcqs, each offering curated multiple-choice questions to sharpen your Heat Transfer knowledge and support exam preparation. Choose a topic below to get started.
| 1. |
What is the total number of concurrent flow regime in the given setup of Shell and Tube HE? |
| A. | 1 |
| B. | 2 |
| C. | 3 |
| D. | 0 |
| Answer» E. | |
| 2. |
What is the total number of counter-current flow regime in the given setup of double split flow? |
| A. | 1 |
| B. | 2 |
| C. | 3 |
| D. | 4 |
| Answer» E. | |
| 3. |
What is the total number of counter-current flow regime in the given setup of split flow? |
| A. | 1 |
| B. | 2 |
| C. | 3 |
| D. | 4 |
| Answer» C. 3 | |
| 4. |
In the following shell and tube setup as shown, recognise the number of Concurrent and Counter-current interactions. |
| A. | 2 concurrent and 4 counter current |
| B. | 3 concurrent and 3 counter current |
| C. | 6 concurrent and 0 counter current |
| D. | 0 concurrent and 6 counter current |
| Answer» C. 6 concurrent and 0 counter current | |
| 5. |
In a shell and tube Heat exchanger, sometimes flow regimes cannot be expressed as concurrent or counter-current. |
| A. | True |
| B. | False |
| Answer» C. | |
| 6. |
In a 1-2 Shell and Tube heat exchanger, how many concurrent and counter current flow regimes are observed? |
| A. | 2 concurrent and 2 counter current |
| B. | 1 concurrent and 1 counter current |
| C. | 4 concurrent and 0 counter current |
| D. | 0 concurrent and 4 counter current |
| Answer» C. 4 concurrent and 0 counter current | |
| 7. |
In the following Figure determine the number of Concurrent flow and Counter-current flow regime. |
| A. | 2 concurrent and 2 counter current |
| B. | 1 concurrent and 1 counter current |
| C. | 2 concurrent and 0 counter current |
| D. | 0 concurrent and 2 counter current |
| Answer» C. 2 concurrent and 0 counter current | |
| 8. |
In a 2-4 Shell and Tube heat exchanger, how many concurrent and counter current flow regimes are observed? |
| A. | 2 concurrent and 2 counter current |
| B. | 1 concurrent and 1 counter current |
| C. | 4 concurrent and 0 counter current |
| D. | 0 concurrent and 4 counter current |
| Answer» B. 1 concurrent and 1 counter current | |
| 9. |
In a shell and tube heat exchanger, the flow pattern is usually ________ |
| A. | Concurrent |
| B. | Counter current |
| C. | Concurrent at a part and Counter current at the other |
| D. | Mixed flow |
| Answer» D. Mixed flow | |